misspelledsearch.com:transformer manufacturerinformation page
If you cannot find the information you are searching for on this page, we suggest searching Google with the correct spelling "transformer manufacturer":
A transformer is an electrical device that transfers energy from one circuit to another by magnetic coupling, with no moving parts. A transformer comprises two or more coupled windings, or a single tapped winding and, in most cases, a magnetic core to concentrate the flux. An alternating current in one winding will induce a current in the other windings. Transformers are used to convert between high and low voltages, to change impedance, and to provide electrical isolation between circuits.
IntroductionThe transformer is one of the simplest of electrical devices. Its basic design, materials, and principles have changed little over the last one hundred years, yet transformer designs and materials continue to be improved. Transformers are essential in high voltage power transmission providing an economical means of transmitting power over large distances. The simplicity, reliability, and economy of conversion of voltages by transformers was the principal factor in the selection of alternating current power transmission in the "War of Currents" in the late 1880's. Single phase pole-mounted step-down transformerAudio-frequency transformers, then referred to as repeating coils, were used by the earliest experimenters in the development of the telephone. While some early electronics applications of the transformer have been replaced by alternative techniques, transformers are still found in many electronic devices. Transformers come in a range of sizes from a thumbnail-sized coupling transformer hidden inside a stage microphone to gigawatt units used to interconnect large portions of national power grids, all operating with the same basic principles and with many similarities in their parts. Transformers alone cannot do the following:
However, transformers are components of the systems that perform all these functions. Basic principlesAn analogyThe transformer may be considered as a simple two-wheel 'gearbox' for electrical voltage and current. The primary winding is analogous to the input shaft and the secondary winding to the output shaft. In this comparison, current is equivalent to shaft speed, voltage to shaft torque. In a gearbox, mechanical power (speed multiplied by torque) is constant (neglecting losses) and is equivalent to electrical power (voltage multiplied by current) which is also constant. The gear ratio is equivalent to the transformer step-up or step-down ratio. A step-up transformer acts analogously to a reduction gear (in which mechanical power is transferred from a small, rapidly rotating gear to a large, slowly rotating gear): it trades current (speed) for voltage (torque), by transferring power from a primary coil to a secondary coil having more turns. A step-down transformer acts analogously to a multiplier gear (in which mechanical power is transferred from a large gear to a small gear): it trades voltage (torque) for current (speed), by transferring power from a primary coil to a secondary coil having fewer turns. Coupling by mutual inductionAn idealised step-down transformer showing resultant flux in the coreA simple transformer consists of two electrical conductors called the primary winding and the secondary winding. If a time-varying voltage is applied to the primary winding of turns, a current will flow in it producing a magnetomotive force (MMF). Just as an electromotive force (EMF) drives current around an electric circuit, so MMF drives magnetic flux through a magnetic circuit. The primary MMF produces a varying magnetic flux in the core (shaded grey), and induces a back electromotive force (EMF) in opposition to . In accordance with Faraday's law of induction, the voltage induced across the primary winding is proportional to the rate of change of flux : Similarly, the voltage induced by this mutual flux across the secondary winding is: With perfect flux coupling, the flux in the secondary winding will be equal to that in the primary winding, and so we can equate and . It thus follows that: Hence in an ideal transformer, the ratio of the primary and secondary voltages is equal to the ratio of the number of turns in their windings, or alternatively, the voltage per turn is the same for both windings. The ratio of the currents in the primary and secondary circuits is inversely proportional to the turns ratio. This leads to the most common use of the transformer: to convert electrical energy at one voltage to energy at a different voltage by means of windings with different numbers of turns. The EMF in the secondary winding, if connected to an electrical circuit, will cause current to flow in the secondary circuit. The MMF produced by current in the secondary opposes the MMF of the primary and so tends to cancel the flux in the core. Since the reduced flux reduces the EMF induced in the primary winding, increased current flows in the primary circuit. The resulting increase in MMF due to the primary current offsets the effect of the opposing secondary MMF. In this way, the electrical energy fed into the primary winding is delivered to the secondary winding. For example, suppose a power of 50 watts is supplied to a resistive load from a transformer with a turns ratio of 25:2.
50 W = 2 V · 25 A in the primary circuit
50 W = 25 V · 2 A in the secondary circuit. In a practical transformer, the higher-voltage winding will have more turns,of smaller conductor cross-section, than the lower-voltage windings. Since a DC voltage source would not give a time-varying flux in the core, no back EMF would be generated and so current flow into the transformer would be unlimited. In practice, the series resistance of the winding limits the amount of current that can flow, until the transformer either reaches thermal equilibrium or is destroyed. The Universal EMF equationIf the flux in the core is sinusoidal, the relationship for either winding between its number of turns, voltage, magnetic flux density and core cross-sectional area is given by the universal emf equation: Where is the sinusoidal root mean square voltage of the winding, is the frequency in hertz, is the number of turns of wire, is the cross-sectional area of the core and is the peak magnetic flux density in tesla. The value 4.44 collects a number of constants required by the system of units. Magnetising current and fluxIn practical transformers, some of the primary current is use to generate a magnetizing flux to magnetise the core. This flux is, in fact, the only resultant flux in the core of a real transformer becuase the primary and secondary fluxes due to the load current cancel to zero. InventionThose credited with the invention of the transformer include:
Practical considerationsClassificationsTransformers are adapted to numerous engineering applications and may be classified in many ways:
Circuit symbolsStandard symbols
LossesAn ideal transformer would have no losses, and would therefore be 100% efficient. In practice energy is dissipated due both to the resistance of the windings (known as copper loss), and to magnetic effects primarily attributable to the core (known as iron loss). Transformers are in general highly efficient, and large power transformers (around 50 MVA and larger) may attain an efficiency as high as 99.75%. Small transformers such as a plug-in "power brick" used to power small consumer electronics may be less than 85% efficient. The losses arise from:
High frequency operationThe universal transformer emf equation indicates that at higher frequency, the core flux density will be lower for a given voltage. This implies that a core can have a smaller cross-sectional area and thus be physically more compact without reaching saturation. It is for this reason that the aircraft manufacturers and the military use 400 hertz supplies. They are less concerned with efficiency, which is lower at higher frequencies (mostly due to increased hysteresis losses), but are more concerned with saving weight. Similarly, flyback transformers which supply high voltage to cathode ray tubes operate at the frequency of the horizontal oscillator, many times higher than 50 or 60 hertz, which allows for a more compact component. ConstructionCoresSteel coresLaminated core transformer showing edge of laminations at top of unit.Transformers for use at power or audio frequencies have cores made of many thin laminations of silicon steel. By concentrating the magnetic flux, more of it is usefully linked by both primary and secondary windings. Since the steel core is conductive, it, too, has currents induced in it by the changing magnetic flux. Each layer is insulated from the adjacent layer to reduce the energy lost to eddy current heating of the core. A typical laminated core is made from E-shaped and I-shaped pieces, leading to the name "EI transformer". Certain types of transformer may have gaps inserted in the magnetic path to prevent magnetic saturation. These gaps may be used to limit the current on a short-circuit, such as for neon sign transformers. A steel core's magnetic hysteresis means that it retains a static magnetic field when power is removed. When power is then reapplied, the residual field will cause a high inrush current until the effect of the remanent magnetism is reduced, usually after a few cycles of the applied alternating current. Overcurrent protection devices such as fuses must be selected to allow this harmless inrush to pass. On transformers connected to long overhead power transmission lines, induced currents due to geomagnetic disturbances during solar storms can cause saturation of the core, and false operation of transformer protection devices. Distribution transformers can achieve low off-load losses by using cores made with amorphous (non-crystalline) steel, so-called "metal glasses" - the high cost of the core material is offset by the lower losses incurred at light load, over the life of the transformer. Solid coresPowdered iron cores are used in circuits (such as switch-mode power supplies) that operate above mains frequencies and up to a few tens of kilohertz. These materials combine high magnetic permeability with high bulk electrical resistivity. At even higher, radio-frequencies (RF), other types of cores made from non-conductive magnetic ceramic materials, called ferrites, are common. Some RF transformers also have moveable cores (sometimes called slugs) which allow adjustment of the coupling coefficient (and bandwidth) of tuned radio-frequency circuits. Air coresHigh-frequency transformers may also use air cores. These eliminate the loss due to hysteresis in the core material. Such transformers maintain high coupling efficiency (low stray field loss) by overlapping the primary and secondary windings. Toroidal coresToroidal transformers are built around a ring-shaped core, which is made from a long strip of silicon steel or permalloy wound into a coil, or from ferrite, depending on frequency. The strip construction ensures that all the grain boundaries are pointing in the optimum direction, making the transformer more efficient by reducing the core's reluctance. The ring shape eliminates the air gaps inherent in the construction of an EI core. The cross-section of the ring is usually square or rectangular, but more expensive cores with circular cross-sections are also available. The primary and secondary coils are wound concentrically to cover the entire surface of the core. This minimises the length of wire needed, and also provides screening to prevent the core's magnetic field from generating electromagnetic interference. Ferrite cores are used at frequencies up to a few tens of kilohertz to reduce losses, particularly in switch-mode power supplies. Toroidal transformers are more efficient (around 95%) than the cheaper laminated EI types. Other advantages, compared to EI types, include smaller size (about half), lower weight (about half), less mechanical hum (making them superior in audio amplifiers), lower exterior magnetic field (about one tenth), low off-load losses (making them more efficient in standby circuits), single-bolt mounting, and more choice of shapes. This last point means that, for a given power output, either a wide, flat toroid or a tall, narrow one with the same electrical properties can be chosen, depending on the space available. The main disadvantage is higher cost. A drawback of toroidal transformer construction is the higher cost of windings. As a consequence, toroidal transformers are uncommon above ratings of a few kVA. Small distribution transformers may achieve some of the benefits of a toroidal core by splitting it and forcing it open, then inserting a bobbin containg primary and secondary windings. When fitting a toroidal transformer, it is important to avoid making an unintentional short-circuit through the core. This can happen if the steel mounting bolt in the middle of the core is allowed to touch metalwork at both ends, which could result in a dangerously large current flowing in the bolt. WindingsIn most practical transformers, the primary and secondary conductors are multi-turn coils of conducting wire because each turn of the coil contributes to the magnetic field, creating a higher magnetic flux density than would a single turn. The wire of adjacent turns and different windings must be electrically insulated from each other. The conducting material used for the winding depends upon the application. Small power and signal transformers are wound with solid copper wire, insulated usually with enamel and sometimes additional insulation. Larger power transformers may be wound with wire, copper or aluminum rectangular conductors, or strip conductors for very heavy currents. High frequency transformers operating in the tens to hundreds of kilohertz will have windings made of Litz wire, to minimize the skin effect losses in the conductors. Large power transformers use multiply-stranded conductors as well, since even at low power frequencies non-uniform distribution of current would otherwise exist in high-current windings. Each strand is insulated from the others, and the strands are arranged so that either at certain points in the winding or throughout the winding, each portion occupies different relative positions in the complete conductor. This "transposition" equalises the current flowing in each strand of the conductor, and reduces eddy current losses in the winding itself. The stranded conductor is also more flexible than a solid conductor of similar size. (see reference (1) below) For signal transformers the windings may be arranged in a way to minimise leakage inductance and stray capacitance, to improve high-frequency response. Windings on both primary and secondary of power transformers may have external connections (called taps) to intermediate points on the winding to allow adjustment of the voltage ratio; taps may be connected to automatic on-load tap changer switchgear for voltage regulation of distribution circuits. Audio-frequency transformers used for distribution of audio to public address loudspeakers have taps to allow adjustment of power supplied to each speaker. A center-tapped transformer is often used in the output stage of an audio power amplifier in a push-pull circuit. Tapped transformers are also used as components of amplifiers, oscillators, and for feedback linearization of amplifier circuits. InsulationThe turns must be insulated from each other to ensure that the current travels through the entire winding: a short-circuit removes some turns from the circuit, severely disrupting transformer operation and overheating power transformers. The potential difference between adjacent turns is usually small, so that enamel insulation is usually sufficient for small power transformers. In power transformers, the voltage difference between windings can be quite large. Insulation may be inserted between separate windings, and also between layers of windings to prevent arcing The transformer may also be immersed in transformer oil that provides further insulation. To ensure that the insulating capability of the transformer oil does not deteriorate, the transformer casing is completely sealed against moisture ingress. The oil serves as both cooling medium to remove heat from the core and coil and as part of the insulation system. ShieldingAlthough an ideal transformer is purely magnetic in operation, the proximity of the primary and secondary windings can create a mutual capacitance between the windings. Where transformers are intended for high electrical isolation between primary and secondary circuits, an electrostatic shield can be placed between windings to minimize this effect. Transformers may also be enclosed by magnetic shields, electrostatic shields, or both to prevent outside interference from affecting the operation of the transformer, or to prevent the transformer from affecting the operation of other devices (such as CRTs in proximity to the transformer). CoolantThree phase dry-type transformer with cover removed; rated about 200 KVA, 480 VSmall signal transformers do not generate significant amounts of heat. Power transformers rated up to a few kilowaats dissipate enough heat to get perceptibly warm, but are kept within permissible temperature limits by natural convective air cooling. Transformers handling rather higher power can be fan-cooled. Specific provision must be made for cooling of high-power transformers. Some dry transformers are enclosed in pressurized tanks and are cooled by nitrogen or sulfur hexafluoride gas. The windings of high-power or high-voltage transformers are immersed in transformer oil—a highly-refined mineral oil that is stable at high temperatures. Large transformers to be used indoors must use a non-flammable liquid. Formerly, polychlorinated biphenyl (PCB) was used as it was not a fire hazard in indoor power transformers and it is highly stable. Due to the stability of PCB and its environmental accumulation, it is no longer permitted in new equipment. Today, nontoxic, stable silicone-based oils or fluorinated hydrocarbons may be used, where the expense of a fire-resistant liquid offsets additional building cost for a transformer vault. Other less-flammable fluids such as canola oil may be used but all fire resistant fluids have some drawbacks in performance, cost, or toxicity compared with mineral oil. The oil cools the transformer, and provides part of the electrical insulation between internal live parts. It has to be stable at high temperatures so that a small short or arc will not cause a breakdown or fire. The oil-filled tank may have radiators through which the oil circulates by natural convection. Very large or high-power transformers (with capacities of millions of watts) may have cooling fans, oil pumps and even oil to water heat exchangers. Oil-filled transformers undergo prolonged drying processes, using vapor-phase heat transfer, electrical self-heating, the application of a vacuum, or combinations of these, to ensure that the transformer is completely free of water vapor before the cooling oil is introduced. This helps prevent electrical breakdown under load. Oil-filled power transformers may be equipped with Buchholz relays - safety devices sensing gas buildup inside the transformer (a side effect of an electric arc inside the windings) and switching off the transformer. Experimental power transformers in the 2 MVA range have been built with superconducting windings which eliminates the copper losses, but not the core steel loss. These are cooled by liquid nitrogen or helium. TerminalsVery small transformers will have wire leads connected directly to the ends of the coils, and brought out to the base of the unit for circuit connections. Larger transformers may have heavy bolted terminals, bus bars or high-voltage insulated bushings made of polymers or porcelain. A large bushing can be a complex structure since it must provide electrical insulation without letting the transformer oil leak. EnclosureSmall transformers often have no enclosure. Transformers may have a shield enclosure, as described above. Larger units may be enclosed to prevent contact with live parts, and to contain the cooling medium (oil or pressurized gas). Transformer designsAutotransformers
An autotransformer has only a single winding, which is tapped at some point along the winding. AC or pulsed voltage is applied across a portion of the winding, and a higher (or lower) voltage is produced across another portion of the same winding. While theoretically separate parts of the winding can be used for input and output, in practice the higher voltage will be connected to the ends of the winding, and the lower voltage from one end to a tap. For example, a transformer with a tap at the center of the winding can be used with 230 volts across the entire winding, and 115 volts between one end and the tap. It can be connected to a 230 volt supply to drive 115 volt equipment, or reversed to drive 230 volt equipment from 115 volts. As the same winding is used for input and output, the flux in the core is partially cancelled, and a smaller core can be used. For voltage ratios not exceeding about 3:1, an autotransformer is cheaper, lighter, smaller and more efficient than a true (two-winding) transformer of the same rating. In practice, transformer losses mean that autotransformers are not perfectly reversible; one designed for stepping down a voltage will deliver slightly less voltage than required if used to step up. The difference is usually slight enough to allow reversal where the actual voltage level is not critical. By exposing part of the winding coils and making the secondary connection through a sliding brush, an autotransformer with a near-continuously variable turns ratio can be obtained, allowing for very small increments of voltage. Polyphase transformersFor three-phase power, three separate single-phase transformers can be used, or all three phases can be connected to a single polyphase transformer. The three primary windings are connected together and the three secondary windings are connected together. The Y-Δ transform is a mathematical technique to simplify analysis of an electrical network.The most common connections are Y-Δ, Δ-Y, Δ-Δ and Y-Y. A vector group indicates the configuration of the windings and the phase angle difference between them. If a winding is connected to earth (grounded), the earth connection point is usually the center point of a Y winding. There are many possible configurations that may involve more or fewer than six windings and various tap connections. Resonant transformersA resonant transformer is one that operates at the resonant frequency of one or more of its coils. The resonant coil, usually the secondary, acts as an inductor, and is connected in series with a capacitor. If the primary coil is driven by a periodic source of alternating current, such as a square or sawtooth wave, each pulse of current helps to build up an oscillation in the secondary coil. Due to resonance, a very high voltage can develop across the secondary, until it is limited by some process such as electrical breakdown. These devices are therefore used to generate high alternating voltages. The current available from this type of coil can be much larger than that from electrostatic machines such as the Van de Graaff generator and Wimshurst machine. They also run at a higher operating temperature than standard units. Examples:-
Other applications of resonant transformers are as coupling between stages of a superheterodyne receiver, where the selectivity of the receiver is provided by the tuned transformers of the intermediate-frequency amplifiers. A voltage regulating transformer uses a resonant winding and allows part of the core to go into saturation on each cycle of the alternating current. This effect stabilizes the output of the regulating transformer, which can be used for equipment that is sensitive to variations of the supply voltage. Saturating transformers provide a simple rugged method to stabilize an ac power supply. However, due to the hysteresis losses accompanying this type of operation, efficiency is low. Instrument transformersCurrent transformersCurrent transformers used as part of metering equipment for three-phase 400 ampere electricity supplyA current transformer is a type of "instrument transformer" that is designed to provide a current in its secondary which is accurately proportional to the current flowing in its primary. Current transformers are commonly used in electricity meters to facilitate the measurement of large currents which would be difficult to measure more directly. Current transformers are usually constructed by passing a single primary turn (either an insulated cable or a copper busbar) through a well-insulated toroidal core wrapped with many turns of wire. Current transformers used by the electrical supply industry are designed to drive 5 ampere (full scale) meters that are appropriately scaled to indicate the measured primary current. These transformers are specified by their input:output current ratio (400:5, 2,000:5, etc.). Specially constructed "wideband current transformers" are also used (usually with an oscilloscope) to measure waveforms of high frequency or pulsed currents. Care must be taken that the secondary of a current transformer is not disconnected from its load while current is flowing in the primary as in this circumstance a dangerously high voltage can be produced across the open secondary. Voltage transformersVoltage transformers (also called potential transformers) are another type of "instrument transformer". They are used by the electricity supply industry to accurately measure high voltages for metering purposes. They are designed to have a precise turns ratio to accurately step down dangerously high voltages so that metering equipment can be operated at a lower (and safer) potential, typically 120 volts. They are designed to present negligible load to the voltage being measured. Pulse transformersA pulse transformer is a transformer that is optimised for transmitting rectangular electrical pulses (that is, pulses with fast rise and fall times and a constant amplitude). Small versions called signal types are used in digital logic and telecommunications circuits, often for matching logic drivers to transmission lines. Medium-sized power versions are used in power-control circuits such as camera flash controllers. Larger power versions are used in the electrical power distribution industry to interface low-voltage control circuitry to the high-voltage gates of power semiconductors such as TRIACs, IGBTs, thyristors and MOSFETs. Special high voltage pulse transformers are also used to generate high power pulses for radar, particle accelerators, or other pulsed power applications. To minimise distortion of the pulse shape, a pulse transformer needs to have low values of leakage inductance and distributed capacitance, and a high open-circuit inductance. In power-type pulse transformers, a low coupling capacitance (between the primary and secondary) is important to protect the circuitry on the primary side from high-powered transients created by the load. For the same reason, high insulation resistance and high breakdown voltage are required. A good transient response is necessary to maintain the rectangular pulse shape at the secondary, because a pulse with slow edges would create switching losses in the power semiconductors. The product of the peak pulse voltage and the duration of the pulse (or more accurately, the voltage-time integral) is often used to characterise pulse transformers. Generally speaking, the larger this product, the larger and more expensive the transformer. RF transformersCoils withTickler For radio frequency use, transformers are sometimes made from configurations of transmission line, sometimes bifilar or coaxial cable, wound around ferrite cores. This style of transformer gives an extremely wide bandwidth, however only a limited number of ratios (such as 1:9, 1:4 or 1:2) can be achieved with this technique. The ferrite increases the inductance dramatically while also lowering its Q factor. The cores of such transformers help performance at the lower frequency end of the band. This style of transformer is frequently used as an impedance matching balun to convert from 300 ohm balanced to 75 ohm unbalanced in FM receivers. Some RF transformers use a tickler feed-back, or regeneration device, in the circuit to properly couple the transformer secondary. Audio transformersTransformers are used in audio to match impedances. This is more necessary with valves/vacuum tubes than with solid-state circuitry, as solid-state components can be used in more flexible circuit arrangements which eliminate the need for transformers. Audio transformers are usually the factor which limit sound quality; electronic circuits with wide frequency response and low distortion are relatively simple to design. A particularly critical component is the output transformer of an audio power amplifier. Valve circuits for quality reproduction have long been produced with no other (inter-stage) audio transformers, but an output transformer is needed to couple the relatively high impedance of the output valve(s) to the low impedance of a loudspeaker. (The valves can deliver a low current at a high voltage; the speakers require high current at low voltage.) For good low-frequency response a relatively large iron core is required; high power handling increases the required core size. Low distortion requires iron of adequate properties; special cores with oriented magnetic domains are used for best results. Good high-frequency response requires carefully designed and implemented windings without excessive leakage inductance or stray capacitance. All this makes for an expensive component. Output transformerless audio power valve amplifiers are possible (e.g., a design by Julius Futterman), but were rarely used due to other disadvantages. Early transistor audio power amplifiers often had output transformers, but they were eliminated as designers came to grips with the new technology. Uses of transformers
See alsoWikibooks has more about this subject: School science/How to make a transformer
External links
References
This transformer manufacturer index site has been developed to help wayward users find the information they are looking for, no matter how they are mistakenly spelled or mistyped. This site is designed to help users find transformer manufacturer information for the following query variants:
If you would like to add or correct the content of this site, or if you are interested in supporting the efforts of misspelledsearch.com by placing your product information on these transformer manufacturer pages, please contact mistype@gmail.com for details. This article is licensed under the GNU Free Documentation License. It uses material from the Wikipedia article "transformer". |